Monday, November 02, 2009

Setting up a build and capture on SCCM2007 for Windows XP SP3

Originally following this guide http://www.windows-noob.com/forums/index.php?/topic/1064-sccm-2007-guides/


Found HRESULT=8007005 and "failed to connect to tstsccm but investigating that error didn't get me anywhere.

The error 0x80040103 combined with LOG[Failed to connect to "\\tstsccm\smspkge$\rc00006 which was the package for the client install that I installed before. per this comment

"if that package definetly exists and you can browse to it from another computer then simply try to recreate the package again (remove old one, delete it from DPs and recreate the package,

sometimes I've seen times where a package looks ok, can be accessed ok but fails in OSD and sometimes the only fix is to rebuild and redistribute the package"

From http://social.technet.microsoft.com/Forums/en-US/configmgrosd/thread/14732dc4-5f5d-4019-8c10-f45f5c5f09cc

I removed and recreated the package and then removed and recreated the task sequence and advertisement. I tried again and got the same error but this time on the package for the boot image.

Researching that error on the boot image led me to this comment
"i think i have cracked it.

i did not set the network access account in the client agent setting initially. once i set that, the task sequence has started. "

from http://www.windows-noob.com/forums/index.php?/topic/587-task-sequence-not-working/page__hl__0x80040103__fromsearch__1

which then gave a link on instructions on how to do this here http://www.windows-noob.com/forums/index.php?/topic/491-how-can-i-configure-sccm-2007-sp1-in-windows-server-2008/

I followed the instructions to configure the client agent properties. I added an account for read access and made it a basic user then added that user.

Tried it again and that worked.